Systematic review of the role of a belly board device in radiotherapy delivery in patients with pelvic malignancies

Radiother Oncol. 2012 Mar;102(3):325-34. doi: 10.1016/j.radonc.2012.02.004. Epub 2012 Feb 22.

Abstract

Purpose: This review analyses the literature concerning the influence of the patient position (supine, prone and prone on a belly board device (BB) on the irradiated small-bowel-volume (SB-V)) and the resulting morbidity of radiation therapy (RT) in pelvic malignancies.

Methods: A literature search was performed in MEDLINE, web of science and Scopus.

Results: Forty-six full papers were found, of which 33 met the eligibility criteria. Fifteen articles focussed on the irradiated SB-V using dose volume histograms (DVHs). Twenty-seven articles studied the patient setup in different patient positions. This review showed that a prone treatment position can result in a lower irradiated SB-V as compared to a supine position, but a more significant reduction of the SB-V can be reached by the additional use of a BB in prone position, for both 3D-CRT and IMRT treatment plans. This reduction of the irradiated SB-V might result in a reduced GI-morbidity. The patient position did not influence the required PTV margins for prostate and rectum.

Conclusions: The irradiated SB-V can be maximally reduced by the use of a prone treatment position combined with a BB for both 3D-CRT and IMRT, which might individually result in a reduction of GI-morbidity.

Publication types

  • Review
  • Systematic Review

MeSH terms

  • Humans
  • Intestine, Small / radiation effects
  • Morbidity
  • Pelvic Neoplasms / epidemiology
  • Pelvic Neoplasms / radiotherapy*
  • Prone Position*
  • Radiotherapy, Conformal / adverse effects
  • Radiotherapy, Conformal / instrumentation*
  • Radiotherapy, Intensity-Modulated / adverse effects
  • Radiotherapy, Intensity-Modulated / instrumentation*
  • Supine Position*