Background: Catheter ablation of persistent atrial fibrillation (AF) is associated with longer procedure times and lower long-term success rates than that of paroxysmal AF.
Objective: To test the hypothesis that restoration/maintenance of sinus rhythm (SR) preablation would facilitate AF termination and improve outcomes in patients with persistent AF.
Methods: We conducted a 2-group cohort study of consecutive patients with persistent AF and SR restored for at least 1 month prior to ablation (SR group; n = 40) and controls matched by age, sex, and AF duration (control group; n = 40). Radiofrequency stepwise catheter ablation was performed in AF for both groups (induced and spontaneous, respectively). Success was defined as freedom from atrial tachyarrhythmia without antiarrhythmic drugs beyond 1 year of follow-up.
Results: During the index ablation procedure, AF cycle length was longer in the SR group than in the control group (183 ± 32 ms vs 166 ± 20 ms; P = .06), suggestive of reverse remodeling. In the SR group, AF more frequently terminated during ablation (95.0% vs 77.5%; P <.05) and required less extensive ablation of complex fractionated electrograms (40.0% vs 87.5%; P <.001) and linear lesions (42.5% vs 82.5%; P <.001). Mean procedural (199.8 ± 69.8 minutes vs 283.5 ± 72.3 minutes; P <.001), fluoroscopy (51.0 ± 24.9 minutes vs 96.3 ± 32.1 minutes; P <.001), and radiofrequency energy delivery (47.5 ± 18.9 minutes vs 97.0 ± 30.6 minutes; P <.001) times were shorter in the SR group. Clinical success rates were similar between groups for first (55.0% vs 45.0%; P = .28) and last (80.0% vs 70.0%; P = .28) procedures, during similar follow-up periods (21.1 ± 9.7 months).
Conclusions: Restoration of SR prior to catheter ablation for persistent AF whenever possible decreases the extent of ablation with the same high clinical efficacy.
Copyright © 2012 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.