Ventricular tachycardia following trans-apical aortic valve replacement

Europace. 2012 Mar;14(3):450-2. doi: 10.1093/europace/eur324. Epub 2011 Oct 19.

Abstract

Transcatheter aortic valve replacement (TAVR) is a relatively new procedure for high-risk patients with severe aortic stenosis. We report a case of a new left ventricular outflow tract ventricular tachycardia following TAVR.

Publication types

  • Case Reports

MeSH terms

  • Adrenergic beta-Antagonists / therapeutic use
  • Aged, 80 and over
  • Aortic Valve Stenosis / surgery*
  • Female
  • Heart Valve Prosthesis Implantation / adverse effects*
  • Heart Valve Prosthesis Implantation / methods
  • Humans
  • Postoperative Complications / drug therapy
  • Tachycardia, Ventricular / drug therapy
  • Tachycardia, Ventricular / etiology*
  • Treatment Outcome

Substances

  • Adrenergic beta-Antagonists