International Pig-a gene mutation assay trial: evaluation of transferability across 14 laboratories

Environ Mol Mutagen. 2011 Dec;52(9):690-8. doi: 10.1002/em.20672. Epub 2011 Sep 11.

Abstract

A collaborative international trial was conducted to evaluate the reproducibility and transferability of an in vivo mutation assay based on the enumeration of CD59-negative rat erythrocytes, a phenotype that is indicative of Pig-a gene mutation. Fourteen laboratories participated in this study, where anti-CD59-PE, SYTO 13 dye, and flow cytometry were used to determine the frequency of CD59-negative erythrocytes (RBC(CD59-)) and CD59-negative reticulocytes (RET(CD59-)). To provide samples with a range of mutant phenotype cell frequencies, male rats were exposed to N-ethyl-N-nitrosourea (ENU) via oral gavage for three consecutive days (Days 1-3). Each laboratory studied 0, 20, and 40 mg ENU/kg/day (n = 5 per group). Three sites also evaluated 4 mg/kg/day. At a minimum, blood samples were collected three times: predosing and on Days 15 and 30. Blood samples were processed according to a standardized sample processing and data acquisition protocol, and three endpoints were measured: %reticulocytes, frequency of RET(CD59-) , and frequency of RBC(CD59-) . The methodology was found to be reproducible, as the analysis of technical replicates resulted in experimental coefficients of variation that approached theoretical values. Good transferability was evident from the similar kinetics and magnitude of the dose-related responses that were observed among different laboratories. Concordance correlation coefficients showed a high level of agreement between the reference site and the test sites (range: 0.87-0.99). Collectively, these data demonstrate that with adequate training of personnel, flow cytometric analysis is capable of reliably enumerating mutant phenotype erythrocytes, thereby providing a robust in vivo mutation assay that is readily transferable across laboratories.

Publication types

  • Research Support, N.I.H., Extramural

MeSH terms

  • Animals
  • CD59 Antigens / genetics
  • Calibration
  • Data Interpretation, Statistical
  • Endpoint Determination
  • Erythrocytes / drug effects
  • Erythrocytes / metabolism
  • Erythrocytes / ultrastructure
  • Ethylnitrosourea / toxicity
  • Flow Cytometry* / methods
  • Flow Cytometry* / standards
  • International Cooperation
  • Laboratories* / standards
  • Membrane Proteins / genetics*
  • Mutagenicity Tests* / methods
  • Mutagenicity Tests* / standards
  • Mutagens / toxicity
  • Mutation*
  • Rats
  • Rats, Inbred F344
  • Rats, Sprague-Dawley
  • Rats, Wistar
  • Reference Standards
  • Reproducibility of Results
  • Reticulocytes / drug effects
  • Reticulocytes / metabolism
  • Reticulocytes / ultrastructure
  • Risk Assessment
  • Time Factors

Substances

  • CD59 Antigens
  • Membrane Proteins
  • Mutagens
  • phosphatidylinositol glycan-class A protein
  • Ethylnitrosourea