J-shaped versus median sternotomy for aortic valve replacement with minimal extracorporeal circuit

Scand Cardiovasc J. 2011 Dec;45(6):379-84. doi: 10.3109/14017431.2011.604875. Epub 2011 Aug 19.

Abstract

Objectives: Minimal access aortic valve replacement (AVR) has been demonstrated to have beneficial effects over median sternotomy. Minimal extracorporeal circulation (MECC) has been shown to have less deleterious effects than conventional cardiopulmonary bypass. We describe for the first time AVR via upper J-shaped partial sternotomy compared to median sternotomy using MECC.

Methods: Prospectively collected pre-operative, intra-operative, post-operative and follow-up data from 104 consecutive patients who underwent minimal access AVR were compared to 72 consecutive patients undergoing median sternotomy using MECC during the same period (January 2007 to December 2009).

Results: No significant differences were found in patient's characteristics or intra-operative data with the exception of pre-existing pulmonary disease. The mean cardiopulmonary bypass (86 ± 18 min vs. 78 ± 15 min, p = 0.0079) and cross-clamp times (65 ± 13 min vs. 59 ± 12 min, p = 0.0013) were significantly shorter in the median sternotomy group. Mediastinal blood loss (397 ± 257 ml vs. 614 ± 339 ml, p < 0.0001) and ventilation time (8 ± 6.9 h vs. 11 ± 16.5 h, p = 0.0054) were significantly less in the minimal access group. No differences were seen in transfusion requirements, inotropic support, intensive care unit (ICU) stay, total hospital stay, post-operative haemoglobin drop, major events or mortality. Quality of life scores after discharge demonstrated less pain with a quicker recovery and return to daily activities in patients receiving J-shaped sternotomy.

Conclusions: Minimal access AVR using MECC is feasible and provides excellent clinical results. Less pain and quicker recovery was experienced among patients in this group.

Publication types

  • Comparative Study

MeSH terms

  • Activities of Daily Living
  • Aged
  • Aged, 80 and over
  • Aortic Valve / surgery*
  • Aortic Valve Stenosis / mortality
  • Aortic Valve Stenosis / surgery*
  • Cardiopulmonary Bypass* / adverse effects
  • Chi-Square Distribution
  • Female
  • Heart Valve Prosthesis Implantation* / adverse effects
  • Heart Valve Prosthesis Implantation* / mortality
  • Humans
  • Intensive Care Units
  • Length of Stay
  • Male
  • Middle Aged
  • Netherlands
  • Postoperative Complications / etiology
  • Postoperative Complications / therapy
  • Prospective Studies
  • Quality of Life
  • Recovery of Function
  • Respiration, Artificial
  • Sternotomy / adverse effects
  • Sternotomy / methods*
  • Surveys and Questionnaires
  • Time Factors
  • Treatment Outcome