Direct sensitive simultaneous determination of fluorinated benzoic acids in oil reservoir waters by ultra high-performance liquid chromatography-tandem mass spectrometry

J Chromatogr A. 2011 Aug 26;1218(34):5872-7. doi: 10.1016/j.chroma.2011.06.028. Epub 2011 Jun 17.

Abstract

A direct ultra-high performance reverse-phase HPLC (UHPLC)--electrospray MS/MS method was developed for the simultaneous determination of 16 fluorinated benzoic acids (FBAs) in oil reservoir waters. The separation was achieved within 5 min in a non-linear gradient mode using a 1-ml sample aliquot. The method detection limits were in the lower ng/ml range (between 0.05 and 50 ng/ml, depending on the compound) owing to the use of the travelling-wave collision cell technology. The method developed was more sensitive, faster (by avoiding sample preconcentration and purification steps) and more robust than the GC/MS methods currently used in oil industries. The accuracy of the method was verified by comparison with GC/MS results. It was applied to the determination of FBAs in water samples coming from reservoir tracing campaigns.

Publication types

  • Evaluation Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Benzoates / chemistry*
  • Chromatography, High Pressure Liquid / methods*
  • Halogenation
  • Sensitivity and Specificity
  • Tandem Mass Spectrometry / methods*
  • Water Pollutants, Chemical / chemistry*

Substances

  • Benzoates
  • Water Pollutants, Chemical