Time- and frequency-domain analyses of atrial fibrillation activation rate: the optical mapping reference

Heart Rhythm. 2011 Nov;8(11):1758-65. doi: 10.1016/j.hrthm.2011.05.007. Epub 2011 May 14.

Abstract

Background: Time- and frequency-domain estimates of activation rate have been proposed to guide atrial fibrillation (AF) ablation in patients, but their electrophysiological correlates are unclear.

Objective: This study sought to examine the relative correlation of average electrical cycle length (CL) and dominant frequency (DF) during AF with reference optical mapping measures.

Methods: Eight sheep hearts were Langendorff-perfused and superfused with oxygenated Tyrode solution inside a tank representing the human thorax. Optical mapping (DI-4-ANEPPS) of 4 × 4 cm2 in the left atrium was performed at 0.5 mm/pixel and 600 fps. A 20-pole catheter was placed in the optical field of view to acquire 1.2-kHz unipolar recordings by the EnSite NavX System (ENS; St. Jude Medical, St. Paul, MN) optimized for CL and DF calculation. During AF, 5-second-long simultaneous optical and electrical signals were analyzed for CL and DF.

Results: During pacing, DF measurements had fewer false results than CL (6.6% to 2.5% vs. 21.5% to 4.4% depending on filtering, P <.001). During AF in regions showing periodic waves on both sides of the catheter optical 1,000/CL versus DF correlation showed 95% confidence identity and was better than unipolar measurements in the ENS (adjusted R(2): 0.58879 vs. 0.12902; P < 10(-6)). DFs of unipolar signals correlated better than CLs with DFs of optical signals. Similarly, bipolar DF correlation with optical DF was not different from identity (P >.157), but the bipolar CL showed smaller identity with the optical CL (P <.0004).

Conclusion: DF values of unipolar and bipolar signals correlate with those of optical signals better than CL values for the respective signals.

Publication types

  • Comparative Study
  • Research Support, N.I.H., Extramural
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Animals
  • Atrial Fibrillation / diagnosis
  • Atrial Fibrillation / physiopathology*
  • Body Surface Potential Mapping / instrumentation*
  • Disease Models, Animal
  • Electrophysiologic Techniques, Cardiac / instrumentation*
  • Equipment Design
  • Follow-Up Studies
  • Sheep