Introduction: Variable stiffness colonoscope may be useful in performing colonoscopies in nonsedated patients or under endoscopist-controlled sedation. The objective of this study is to evaluate whether this instrument facilitates colonoscopy in patients under deep sedation monitored by an anaesthesiologist.
Methods: Prospective and randomized study enroling consecutive patients referred for colonoscopy under deep sedation monitored by an anaesthesiologist. In group I, a variable stiffness colonoscope was used, whereas in group II, a standard colonoscope was used. The main variable was the need to change the position of the patient during the endoscopy.
Results: Fifty-six patients were included in group I (variable stiffness colonoscope) and 54 in group II (standard colonoscope). The caecum was reached in 92.9% of patients in group I and in 90.7% of group II (P=0.7). The time required to reach the caecum was significantly less in group I (6.14±3.5 vs. 7.7±3.8; P=0.035). The variable stiffness colonoscope was effective in 66.7% of cases. Changing the position of the patient was necessary in 12.5% of cases in group I compared with 33.3% of cases in group II (P=0.01).
Conclusion: The variable stiffness colonoscope avoids the need to change the patient's position and reduces caecal intubation time in patients undergoing colonoscopy under deep sedation controlled by an anaesthesiologist.