Angular stability potentially permits fewer locking screws compared with conventional locking in intramedullary nailed distal tibia fractures: a biomechanical study

J Orthop Trauma. 2011 Jun;25(6):340-6. doi: 10.1097/BOT.0b013e3182163345.

Abstract

Objectives: To compare mechanical stability of angle-stable locking construct with four screws with conventional five screw locking in intramedullary nailed distal tibia fractures under cyclic loading.

Methods: Ten pairs of fresh-frozen human cadaveric tibiae were intramedullary nailed and assigned to either an angle-stable locking construct consisting of four screws or conventional five-screw locking. After simulating an unstable distal two-fragmental 42-A3.1 fracture, the specimens were mechanically tested under quasistatic and cyclic sinusoidal axial and torsional loading.

Results: Bending stiffness of the angle-stable and the conventional fixation was 644.3 N/° and 416.5 N/°, respectively (P = 0.075, power 0.434). Torsional stiffness of the angle-stable locking (1.91 Nm/°) was significantly higher compared with the conventional one (1.13 Nm/°; P = 0.001, power 0.981). Torsional play of the angle-stable fixation (0.08°) was significantly smaller compared with the conventional one (0.46°; P = 0.002, power 0.965). The angle-stable locking revealed significantly less torsional deformation in the fracture gap after one cycle (0.74°) than the conventional one (1.75°; P = 0.005, power 0.915) and also after 1000 cycles (angle-stable: 1.56°; conventional: 2.51°; P = 0.042, power 0.562). Modes of failure were fracture of the distal fragment, loosening of distal locking screws, nail breakage, and their combination, equally distributed between the groups (P = 0.325).

Conclusions: Both the angle-stable locking technique using four screws and conventional locking consisting of five screws showed high biomechanical properties. Hence, angle-stable locking reflects a potential to maintain fixation stability while reducing the number of locking screws compared with conventional locking in intramedullary nailed unstable distal tibia fractures.

Publication types

  • Comparative Study
  • Evaluation Study

MeSH terms

  • Aged
  • Bone Nails*
  • Cadaver
  • Elastic Modulus
  • Equipment Failure Analysis
  • Female
  • Fracture Fixation, Internal / instrumentation*
  • Humans
  • Male
  • Middle Aged
  • Prosthesis Design
  • Tensile Strength
  • Tibial Fractures / physiopathology*
  • Tibial Fractures / surgery*
  • Treatment Outcome