Simple and sensitive method for determination of imidacloprid residue in soil and water by HPLC

Bull Environ Contam Toxicol. 2011 May;86(5):554-8. doi: 10.1007/s00128-011-0245-8. Epub 2011 Apr 1.

Abstract

A rapid, sensitive and reliable HPLC method was developed and validated for the determination of imidacloprid residue in water at different pH and in soil. Quantification was performed by reversed phase HPLC system equipped with UV detector. The limit of quantification (LOQ) was found to be 0.02 mg/kg in soil and 0.02 mg/L in water. The limit of detection (LOD) was 0.006 mg/kg in soil and 0.006 mg/L in water. Recoveries for imidacloprid were 95.18%, 94.66%, 95.27% and 94.78% in black, red, sandy loam and clay soils, respectively. Recoveries for imidacloprid from water were 96.86%, 86.14%, and 92.34% at pH values of 4, 7, and 9, respectively.

MeSH terms

  • Chromatography, High Pressure Liquid
  • Environmental Monitoring / instrumentation
  • Environmental Monitoring / methods*
  • Environmental Pollutants / analysis*
  • Fresh Water / chemistry*
  • Hydrogen-Ion Concentration
  • Insecticides / analysis*
  • Pesticide Residues / analysis*
  • Soil / chemistry*

Substances

  • Environmental Pollutants
  • Insecticides
  • Pesticide Residues
  • Soil