Quantitative analysis of liver function using superparamagnetic iron oxide- and Gd-EOB-DTPA-enhanced MRI: comparison with Technetium-99m galactosyl serum albumin scintigraphy

Eur J Radiol. 2012 Jun;81(6):1100-4. doi: 10.1016/j.ejrad.2011.02.053. Epub 2011 Mar 23.

Abstract

Purpose: To examine whether or not the parameters regarding the signal intensity of the liver parenchyma on superparamagnetic iron oxide (SPIO)- and gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced MRI are correlated with the parameters of Technetium-99m galactosyl serum albumin ((99m)Tc-GSA) scintigraphy.

Materials and methods: This retrospective study consisted of 55 and 33 patients who underwent SPIO- and Gd-EOB-DTPA-enhanced MRI in addition to (99m)Tc-GSA scintigraphy, respectively. For each patient, we calculated Pre R2* and Pre R2, which are equivalent to R2* (=1/T2*) and R2 (=1/T2) values of the liver parenchyma; ΔR2* and ΔR2, which represent differences in R2* and R2 values of the liver parenchyma before and after administration of SPIO; and the increase rates of both the liver-to-spleen signal intensity ratio (LSR) and the liver-to-major psoas muscle signal intensity ratio (LMR) on the hepatobiliary phase compared with the precontrast image. For (99m)Tc-GSA scintigraphy, the receptor index LHL15 and the blood clearance index HH15 were recorded.

Results: Regression analysis showed a moderate correlation between Pre R2* and LHL15 (P<0.05). Mild to moderate correlations were also obtained between any combination of ΔR2* and ΔR2 on the one hand, and LHL15 and HH15 on the other (P<0.05). There were moderate correlations between any combination of increase rates of LSR and LMR on the one hand, and LHL15 and HH15 on the other (P<0.05-0.001).

Conclusion: Pre R2*, ΔR2*, ΔR2 and the increase rates of LSR and LMR could be used as quantitative indicators of liver function.

Publication types

  • Comparative Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Aged, 80 and over
  • Contrast Media*
  • Dextrans*
  • Female
  • Gadolinium DTPA
  • Humans
  • Image Interpretation, Computer-Assisted
  • Liver Function Tests
  • Liver Neoplasms / diagnosis*
  • Liver Neoplasms / diagnostic imaging
  • Magnetic Resonance Imaging / methods*
  • Magnetite Nanoparticles*
  • Male
  • Middle Aged
  • Radionuclide Imaging
  • Radiopharmaceuticals*
  • Regression Analysis
  • Retrospective Studies
  • Technetium Tc 99m Aggregated Albumin
  • Technetium Tc 99m Pentetate

Substances

  • Contrast Media
  • Dextrans
  • Magnetite Nanoparticles
  • Radiopharmaceuticals
  • Technetium Tc 99m Aggregated Albumin
  • gadolinium ethoxybenzyl DTPA
  • technetium Tc 99m DTPA-galactosyl-human serum albumin
  • ferumoxides
  • Gadolinium DTPA
  • Technetium Tc 99m Pentetate