A higher chest compression rate may be necessary for metronome-guided cardiopulmonary resuscitation

Am J Emerg Med. 2012 Jan;30(1):226-30. doi: 10.1016/j.ajem.2010.11.026. Epub 2011 Jan 3.

Abstract

Objectives: Metronome guidance is a simple and economical feedback system for guiding cardiopulmonary resuscitation (CPR). However, a recent study showed that metronome guidance reduced the depth of chest compression. The results of previous studies suggest that a higher chest compression rate is associated with a better CPR outcome as compared with a lower chest compression rate, irrespective of metronome use. Based on this finding, we hypothesized that a lower chest compression rate promotes a reduction in chest compression depth in the recent study rather than metronome use itself.

Methods: One minute of chest compression-only CPR was performed following the metronome sound played at 1 of 4 different rates: 80, 100, 120, and 140 ticks/min. Average compression depths (ACDs) and duty cycles were compared using repeated measures analysis of variance, and the values in the absence and presence of metronome guidance were compared.

Results: Both the ACD and duty cycle increased when the metronome rate increased (P = .017, <.001). Average compression depths for the CPR procedures following the metronome rates of 80 and 100 ticks/min were significantly lower than those for the procedures without metronome guidance.

Conclusions: The ACD and duty cyle for chest compression increase as the metronome rate increases during metronome-guided CPR. A higher rate of chest compression is necessary for metronome-guided CPR to prevent suboptimal quality of chest compression.

Publication types

  • Randomized Controlled Trial

MeSH terms

  • Cardiopulmonary Resuscitation / methods*
  • Cross-Over Studies
  • Heart Massage / methods*
  • Humans
  • Patient Simulation
  • Time Factors