Electrochemical behaviour and surface characterisation of Zr exposed to an SBF solution containing glycine, in view of dental implant applications

J Mater Sci Mater Med. 2011 Jan;22(1):193-200. doi: 10.1007/s10856-010-4187-1. Epub 2010 Nov 24.

Abstract

Zr and Ti alloys are extensively used in the biomedical field owing to their optimal mechanical properties and excellent corrosion resistance. Fully ceramic implants based on zirconia are appealing with respect to the traditional Ti-based metallic ones for several reasons, such as: (i) improved aesthetic impact, (ii) better biocompatibility and (iii) better osteointegration. Nevertheless, fully ceramic implants exhibit serious mechanical and clinical drawbacks, chiefly brittleness and impossibility of post-implant position adjustments. In this paper we propose the novel approach of using a metal-based system, consisting of metallic Zr, for the bulk of the implant and an electrochemically grown zirconia coating, ensuring contact of the ceramic with the biological environment and isolation from the underlying metal. This solution combines the outstanding mechanical properties of the metal in the bulk with the optimal biochemical properties exclusively where they are needed: at the surface. The present paper-focussed on the electrochemical behaviour of the proposed system at the implant-wound and implant-growing bone interface-reports a time-dependent electrochemical corrosion study of zirconia-coated zirconium, performed in the following ways: (i) exposure and measurements in SBF (simulating the inorganic part of human plasma, relevant to wound chemistry), (ii) exposure and measurements in SBF with added glycine (the simplest, ubiquitous amino acid found in proteins), (iii) exposure in SBF with added glycine and measurements in SBF. Electrochemical impedance spectra were measured and interpreted with the equivalent-circuit approach, yielding estimates of the time-variation of the oxide film thickness and resistance were estimated. FT-IR, Surface Raman and VIS reflectance spectroscopies were used to characterise the surface before and after the exposure to SBF solutions. Spectroelectrochemical measurements revealed an higher corrosion resistance of the oxide films formed on Zr in the presence of glycine in the SBF matrix and a smoother electrode surface.

Publication types

  • Evaluation Study

MeSH terms

  • Body Fluids / chemistry
  • Body Fluids / metabolism
  • Body Fluids / physiology*
  • Coated Materials, Biocompatible / chemistry
  • Dental Implants*
  • Electrochemistry
  • Glycine / chemistry
  • Glycine / pharmacology*
  • Humans
  • Materials Testing*
  • Microscopy, Electron, Scanning
  • Models, Biological
  • Solutions / chemistry
  • Solutions / pharmacology
  • Spectroscopy, Fourier Transform Infrared
  • Spectrum Analysis, Raman
  • Surface Properties
  • X-Ray Diffraction
  • Zirconium / chemistry*

Substances

  • Coated Materials, Biocompatible
  • Dental Implants
  • Solutions
  • Zirconium
  • Glycine