Monitoring platelet dependent thrombin generation in mice

Thromb Res. 2010 Nov;126(5):436-41. doi: 10.1016/j.thromres.2010.08.007. Epub 2010 Sep 16.

Abstract

Calibrated automated thrombin generation assay was adapted to measure thrombin generation in platelet rich plasma from mice. Vena cava phlebotomy appeared the best technique for blood sampling. The concentration-effect curves of tissue factor and platelet count have been determined. Corn trypsin inhibitor 2μM inhibits contact activation effectively. Recombinant human thrombomodulin does not inhibit thrombin generation in mouse plasma but activated protein C (20nM) does. Thrombin generation was dose dependently diminished by low molecular weight heparin and increased by high concentrations of exogenous factor VIII i.e. the assay can detect both hypo- and hypercoagulability.

MeSH terms

  • Animals
  • Blood Coagulation Factors / physiology*
  • Blood Coagulation Tests
  • Blood Platelets / cytology
  • Blood Platelets / metabolism*
  • Humans
  • Mice
  • Mice, Inbred C57BL
  • Platelet Count
  • Thrombin / metabolism*

Substances

  • Blood Coagulation Factors
  • Thrombin