The upside-down stentless aortic bioprosthesis to tricuspid valve replacement

J Cardiovasc Med (Hagerstown). 2010 Oct;11(10):762-3. doi: 10.2459/JCM.0b013e328335d062.

Abstract

Between March 2008 and January 2009, a stentless tricuspid valve replacement (STVR) was performed in three patients with tricuspid valve endocarditis who were resistant to medical therapy. Intraoperative and follow-up echocardiograms revealed good prosthetic function without stenosis or regurgitation. This technique could be considered an additional surgical option to stented biological valves or homograft implantations in very high risk populations.

Publication types

  • Case Reports

MeSH terms

  • Adult
  • Bioprosthesis*
  • Endocarditis / pathology
  • Endocarditis / physiopathology
  • Endocarditis / surgery*
  • Female
  • Heart Valve Prosthesis Implantation / instrumentation*
  • Heart Valve Prosthesis*
  • Humans
  • Male
  • Middle Aged
  • Prosthesis Design
  • Treatment Outcome
  • Tricuspid Valve / pathology
  • Tricuspid Valve / physiopathology
  • Tricuspid Valve / surgery*
  • Tricuspid Valve Insufficiency / pathology
  • Tricuspid Valve Insufficiency / physiopathology
  • Tricuspid Valve Insufficiency / surgery*