[Male stress urinary incontinence by InVance bone anchored sub-urethral sling: Predictive factors of treatment failure: Multicentric study by the CTMH-AFU]

Prog Urol. 2009 Dec;19(11):839-44. doi: 10.1016/j.purol.2009.04.013. Epub 2009 Jun 21.
[Article in French]

Abstract

Aim: To define predictive factors of treatment failure in a multicentric study for the treatment of stress male urinary incontinence by InVance (American Medical System, USA) bone anchored sub-urethral sling.

Method: Cases treated by InVance between January 2005 and December 2007 in four French academic centers were collected.

Results: Eighty-four patients were evaluated. Mean age was 68 years old. With a mean follow-up of 20 months, 38 patients (45%) were dry, 22 (26%) were improved, and 24 (29%) suffered treatment failure. In univariate analysis, three parameters were significantly associated with treatment failure, including severe urinary incontinence (P=0.005), urodynamic instability (P=0.043), and incontinence due to a bitherapy including external radiotherapy (P=0.031). If zero or one versus two or three risk factors were present, treatment failure rate was 25 and 67%, respectively (P=0.013). In multivariate analysis, bitherapy including radiotherapy was the sole independent treatment failure risk factor (P=0.017).

Conclusion: Two patient groups were defined, allowing to determine preoperatively good candidates and bad candidates for stress urinary incontinence treatment by InVance sling.

Publication types

  • English Abstract
  • Multicenter Study

MeSH terms

  • Aged
  • Humans
  • Male
  • Risk Factors
  • Suburethral Slings*
  • Treatment Failure
  • Urinary Incontinence, Stress / surgery*