Measured posterior annuloplasty for repair of non-ischemic mitral regurgitation. A single unit follow-up

Interact Cardiovasc Thorac Surg. 2010 Jan;10(1):81-5. doi: 10.1510/icvts.2009.215798. Epub 2009 Oct 30.

Abstract

The aim of this report is to evaluate short- and long-term outcomes of annuloplasty method of our choice: measured posterior annuloplasty (MPA). MPA is a piece of a Duran ring cut to the length of free-edge of anterior mitral leaflet (AML) and anchored with multiple pledgeted U-sutures from trigone to trigone into the posterior annulus.

Material and methods: From 1988 to 2000, 103 consecutive patients with non-ischemic mitral regurgitation were scheduled preoperatively to be repaired by MPA.

Results: Preoperative mitral valve regurgitation (MR) grade was 3.8+/-0.5 and decreased to 0.1+/-0.3 (P<0.0001) after repair. One patient was converted to insertion of mechanical prosthesis after grade 3 MR persisted after septal myectomy and MPA. Three patients needed instant revision of the repair one due to SAM and two due to stenosis. No patient had a stenosis or unacceptable (>1) MR after the procedure. There was one operative death (1.0%) and 3 hospital/30-day deaths (2.9%). Sixteen patients (16.3%) expired during the follow-up to 91 months (mean 57.4+/-19.5, median 60 months) none due to failure of MPA. There were no reoperations due to failure of MPA. Three patients had a reoperation, one for dehiscence of reconstruction after P2 resection and two patients due to progression of anterior leaflet degeneration and calcification with 4+ MR. New York Heart Association (NYHA) functional classification decreased from 2.3+/-0.8 to 1.4+/-0.6 (P<0.0001) and only one patient had an increase from II to III. Eighty-eight patients (96.7%) were in NYHA class I-II. Ten patients had an increase of MR from 0 to trace or 1 and one from 0 to 2. Two patients were diagnosed with mild stenosis without need of reoperation.

Conclusions: MPA is a durable and stable alternative for repair of non-ischemic mitral regurgitation of different etiologies. The technique gives an objective measure of the length of the band and no patient is left with a significant MR or mitral valve stenosis (MS). First-time success rate is very high and instant repairs few and minor. Freedom of MPA related reoperations is 100%.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Aged, 80 and over
  • Female
  • Follow-Up Studies
  • Heart Valve Prosthesis
  • Heart Valve Prosthesis Implantation / adverse effects
  • Heart Valve Prosthesis Implantation / instrumentation
  • Heart Valve Prosthesis Implantation / methods*
  • Heart Valve Prosthesis Implantation / mortality
  • Hospital Mortality
  • Humans
  • Kaplan-Meier Estimate
  • Logistic Models
  • Male
  • Middle Aged
  • Mitral Valve Insufficiency / etiology
  • Mitral Valve Insufficiency / mortality
  • Mitral Valve Insufficiency / surgery*
  • Prosthesis Design
  • Reoperation
  • Retrospective Studies
  • Risk Assessment
  • Risk Factors
  • Severity of Illness Index
  • Suture Techniques
  • Time Factors
  • Treatment Outcome
  • Young Adult