Accuracy of cardiac magnetic resonance of absolute myocardial blood flow with a high-field system: comparison with conventional field strength

JACC Cardiovasc Imaging. 2009 Sep;2(9):1103-10. doi: 10.1016/j.jcmg.2009.06.009.

Abstract

Objectives: The aim of this study was to determine the accuracy of cardiac magnetic resonance (CMR) first pass (FP) perfusion measures of absolute myocardial blood flow (MBF) with a 3.0-T magnet and compare these measures with FP perfusion at 1.5-T with absolute MBF by labeled microspheres as the gold standard.

Background: First-pass magnetic resonance (MR) myocardial perfusion imaging can quantify MBF, but images are of low signal at conventional magnetic field strength due to the need for rapid acquisition.

Methods: A pig model was used to alter MBF in a coronary artery during FP CMR (intracoronary adenosine followed by ischemia). This produces an active zone with a range of MBF and a control zone. Microspheres were injected into the left atrium with concurrent reference sampling. FP MR perfusion imaging was performed at 1.5-T (n = 9) or 3.0-T (n = 8) with a saturation-recovery gradient echo sequence in short-axis slices during a bolus injection of 0.025 mmol/kg gadolinium-diethylenetriamine pentaacetic acid. Fermi function deconvolution was performed on active and control region of interest from short-axis slices with an arterial input function derived from the left ventricular cavity. These MR values of MBF were matched to microsphere values obtained from short-axis slices at pathology.

Results: Occlusion MBF was 0.21 +/- 0.26 ml/min/g, adenosine MBF was 2.28 +/- 0.99 ml/min/g, and control zone MBF was 0.70 +/- 0.22 ml/min/g. The correlation of MR FP CMR with microsphere was close for both field strengths: 3.0-T, r = 0.98, p < 0.0001 and 1.5-T, r = 0.95, p < 0.0001. The 95% confidence limits of agreement were slightly narrower at 3.0-T (3.0-T = 0.49 ml/min/g, 1.5-T = 0.68 ml/min/g, p < 0.05). The FP CMR image characteristics were better at 3.0-T (noise and contrast enhancement were both superior at 3.0-T). In myocardial zones where MBF <0.50 ml/min/g, the correlation with microspheres was closer at 3.0-T (r = 0.55 at 1.5-T, r = 0.85 at 3.0-T).

Conclusions: Absolute MBF by FP perfusion imaging is accurate at both 1.5- and 3.0-T. Signal quality is better at 3.0-T, which might confer a benefit for estimating MBF in ischemic zones.

Publication types

  • Comparative Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adenosine
  • Animals
  • Contrast Media
  • Coronary Circulation*
  • Disease Models, Animal
  • Gadolinium DTPA
  • Hyperemia / chemically induced
  • Hyperemia / diagnosis*
  • Hyperemia / physiopathology
  • Magnetic Resonance Imaging*
  • Microspheres
  • Myocardial Ischemia / diagnosis*
  • Myocardial Ischemia / physiopathology
  • Myocardial Perfusion Imaging / methods*
  • Predictive Value of Tests
  • Reproducibility of Results
  • Swine
  • Time Factors

Substances

  • Contrast Media
  • Gadolinium DTPA
  • Adenosine