Dilatation of aortic grafts over time: what to expect and when to be concerned

Semin Vasc Surg. 2009 Jun;22(2):119-24. doi: 10.1053/j.semvascsurg.2009.04.002.

Abstract

Dilatation of aortic prosthetic grafts is commonly reported, but most reports are anecdotal, with little objective data in the literature. We performed a prospective trial of 303 patients who underwent prosthetic graft repair for aortic aneurysm or occlusive disease, randomizing patients between insertion of a woven polyester or expanded polytetrafluoroethylene (ePTFE) graft. Patients were followed with computed tomography and ultrasonography for up to 5 years in order to assess the frequency and magnitude of postoperative dilatation. Graft dilatation was documented in patients with polyester grafts at 12 months. Thereafter and up to 60 months, polyester grafts did not dilate further. After 5 years, polyester prostheses had dilated by 25% and ePTFE by 12.5%, as determined by computed tomography imaging. These observations suggest that dilatation of prosthetic grafts is more frequent with knitted polyester grafts compared with ePTFE. Dilatation occurs within the first year after implantation and can be, in part, explained by a discrepancy between the initial nominal graft diameter and its diameter after clamp release, probably due to an in vivo adaptation of the textile structure. Interestingly, graft dilatation did not appear to be associated with an increased frequency of graft-related complications.

Publication types

  • Comparative Study
  • Randomized Controlled Trial

MeSH terms

  • Aged
  • Aortic Aneurysm / diagnostic imaging
  • Aortic Aneurysm / surgery*
  • Aortic Diseases / diagnostic imaging
  • Aortic Diseases / surgery*
  • Aortography / methods
  • Arterial Occlusive Diseases / diagnostic imaging
  • Arterial Occlusive Diseases / surgery*
  • Blood Vessel Prosthesis Implantation / adverse effects
  • Blood Vessel Prosthesis Implantation / instrumentation*
  • Blood Vessel Prosthesis*
  • Female
  • Humans
  • Male
  • Middle Aged
  • Polyesters
  • Polytetrafluoroethylene
  • Prospective Studies
  • Prosthesis Design
  • Prosthesis Failure*
  • Time Factors
  • Tomography, X-Ray Computed
  • Treatment Failure
  • Ultrasonography

Substances

  • Polyesters
  • Polytetrafluoroethylene