From the donor's arm to blood product: a study on bacterial contamination of apheresis platelet concentrates

Blood Transfus. 2007 Jul;5(3):130-3. doi: 10.2450/2007.0003-07.

Abstract

Background: Transfusion-associated bacterial infections are a quite frequent collateral effect of administration of platelet concentrates (PC). We carried out a microbiological surveillance of bacterial contamination of apheresis platelet concentrates by studying microbial flora on donors' arms before and after skin disinfection, through blood cultures with the diversion volume and with the PC.

Materials and methods: Platelet aphereses were carried out using two Haemonetics MCS+ instruments. Cutaneous swabs were examined by the direct plate technique and blood cultures were performed using Bact/ALERT aerobic bottles. In the 5 years from January 2001 to December 2005 we tested 481 PC.

Results: Cutaneous swabs showed significant bacterial growth in 89% of cases before skin disinfection and in 44% after. None of the blood cultures performed on diversion blood was positive, one (0.2%) PC was positive on the fifth day after collection and the presence of a Staphylococcus epidermidis strain was demonstrated.

Conclusions: Our results suggest that the skin disinfection protocol adopted in our structure is not fully satisfactory. The cultures performed on the PC showed a low prevalence of contamination, and the only positive sample was contaminated by a common skin contaminant (S. epidermidis). The culture became positive on the fifth day after collection, but on the second day the PC had been transfused to a patient, without any adverse reaction. In our experience a culture method using Bact/ALERT aerobic bottles was not able to prevent transfusion of the only contaminated PC identified in this study.

Keywords: apheresis; arm disinfection; microbiological contamination; platelet concentrates.