Dose escalation in the radiotherapy of non-small-cell lung cancer with aperture-based intensity modulation and photon beam energy optimization for non-preselected patients

Radiother Oncol. 2009 Jun;91(3):342-8. doi: 10.1016/j.radonc.2008.11.017. Epub 2009 Jan 8.

Abstract

Purpose: To verify the potential of aperture-based intensity-modulated radiotherapy (AB-IMRT) to realize dose escalation plans for non-preselected non-small-cell lung cancer (NSCLC) patients, using photon beam energy optimization.

Methods and materials: Seven cases of NSCLC were retrospectively studied. Clinical reference plans were made at 60 Gy by an experienced dosimetrist. Dose escalation was applied to PTV2, a subvolume within the main PTV1. Escalation plans were optimized by considering beam angles (table and gantry), energy (6 and 23 MV) and weights, for an increasing dose to the PTV2, starting from 66 Gy and keeping 30 fractions.

Results: In five cases, doses over 78 Gy could be achieved before exceeding organs at risk (OARs) standard tolerance. Peripheral overdosages, as well as lung and spinal cord tolerance doses, limited escalation. Means+/-SD V(95%) parameters were (97.3+/-0.9)% for PTV1s and (96.7+/-2.2)% for PTV2s. Doses to OARs were also maintained at acceptable levels. Optimized plans made use of both low- and high-energy beams and had a similar number of monitor units compared to the 60 Gy clinical plans.

Conclusions: The AB-IMRT system can successfully realize dose escalation for a sizeable number of cases. Plans produced contained few large segments, and are applicable to a wide range of tumor volumes and locations.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Carcinoma, Non-Small-Cell Lung / pathology
  • Carcinoma, Non-Small-Cell Lung / radiotherapy*
  • Dose Fractionation, Radiation
  • Dose-Response Relationship, Radiation
  • Humans
  • Imaging, Three-Dimensional
  • Lung Neoplasms / pathology
  • Lung Neoplasms / radiotherapy*
  • Photons / therapeutic use
  • Radiation Protection
  • Radiotherapy Dosage
  • Radiotherapy Planning, Computer-Assisted / methods*
  • Radiotherapy, Intensity-Modulated / methods*
  • Retrospective Studies
  • Treatment Outcome