Determination of vitamin K1 in plasma by solid phase extraction and HPLC with fluorescence detection

J Chromatogr B Analyt Technol Biomed Life Sci. 2009 Jan 15;877(3):351-4. doi: 10.1016/j.jchromb.2008.12.044. Epub 2008 Dec 25.

Abstract

We describe a procedure for quantification of vitamin K(1) in human plasma by HPLC. Samples, enriched with a vitamin K derivative as internal standard, were deproteinized, purified on polymeric RP-SPE cartridges and injected into HPLC equipped with a post-column on-line zinc metal reactor and a fluorometric detector. Median level in blood donors (n=87) was 1.967 nmol/L (0.93-4.01, 5th-95th percentiles), with a significant correlation between plasma levels and age (r=0.276, p=0.00958) and a lower (not significant) value in women than in men. This method, easy-to-handle and with a high throughput, can be used to identify covert states of vitamin K intake deficiency in patients thus at risk of alterations in blood clotting or bone mineralization.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Aged
  • Analysis of Variance
  • Chromatography, High Pressure Liquid / methods*
  • Female
  • Fluorescence
  • Humans
  • Linear Models
  • Male
  • Middle Aged
  • Reference Standards
  • Solid Phase Extraction / methods*
  • Vitamin K 1 / blood*

Substances

  • Vitamin K 1