Persistent fainting after implantation of a "curative" pacemaker

N Engl J Med. 2009 Jan 1;360(1):88-9. doi: 10.1056/NEJMc0807099.
No abstract available

Publication types

  • Case Reports
  • Letter

MeSH terms

  • Bradycardia / diagnosis
  • Bradycardia / etiology
  • Diagnostic Errors
  • Electrocardiography
  • Electroencephalography
  • Epilepsy, Temporal Lobe / complications
  • Epilepsy, Temporal Lobe / diagnosis*
  • Humans
  • Male
  • Middle Aged
  • Pacemaker, Artificial*
  • Syncope / etiology*