Real-time simulation of 4D lung tumor radiotherapy using a breathing model

Med Image Comput Comput Assist Interv. 2008;11(Pt 2):710-7. doi: 10.1007/978-3-540-85990-1_85.

Abstract

In this paper, we present a real-time simulation and visualization framework that models a deformable surface lung model with tumor, simulates the tumor motion and predicts the amount of radiation doses that would be deposited in the moving lung tumor during the actual delivery of radiation. The model takes as input a subject-specific 4D Computed Tomography (4D CT) of lungs and computes a deformable lung surface model by estimating the deformation properties of the surface model using an inverse dynamics approach. Once computed, the deformable model is used to simulate and visualize lung tumor motion that would occur during radiation therapy accounting for variations in the breathing pattern. A radiation treatment plan for the lung tumor is developed using one of the 4D CT phases. During the simulation of radiation delivery, the dose on the lung tumor is computed for each beam independently.

Publication types

  • Evaluation Study

MeSH terms

  • Algorithms
  • Computer Simulation
  • Computer Systems
  • Humans
  • Imaging, Three-Dimensional / methods*
  • Lung Neoplasms / diagnostic imaging*
  • Lung Neoplasms / radiotherapy*
  • Models, Biological*
  • Motion
  • Radiographic Image Enhancement / methods
  • Radiographic Image Interpretation, Computer-Assisted / methods
  • Radiotherapy, Computer-Assisted / methods*
  • Radiotherapy, Conformal / methods*
  • Reproducibility of Results
  • Respiratory Mechanics*
  • Sensitivity and Specificity