Utility of terminal hemadsorption for detection of hemadsorbing respiratory viruses from conventional shell vial cultures for laboratories using R-Mix cultures

J Clin Virol. 2009 Jan;44(1):86-7. doi: 10.1016/j.jcv.2008.08.019. Epub 2008 Oct 9.

Abstract

Background: Many laboratories using R-Mix cell lines inoculate other shell vial cultures to improve the recovery of viruses, and in particular, perform terminal hemadsorption (THad) following 10-14 days of incubation to improve detection of respiratory viruses. We explored the cost-effectiveness and added benefits of THad on conventional shell vial cultures from respiratory samples for laboratories using R-Mix cell lines.

Objectives: To determine if eliminating the practice of THad from conventional shell vial culture when R-Mix cultures are negative, would result in a significant reduction in the number of hemadsorbing respiratory viruses detected.

Study design: THad results were retrospectively reviewed for 41,129 respiratory shell vial cultures that were set up concurrently with R-Mix cultures.

Results: Greater than 95% of hemadsorbing respiratory viruses were recovered by R-Mix standard protocol within 24h of inoculation, and only 5% were detected by THad at 10-14 days.

Conclusion: The practice of hemadsorption at days 10-14 for conventional shell vial cultures from respiratory specimens should be discontinued for laboratories using R-Mix due to its low yield, questionable clinical impact of delayed results and additional costs.

MeSH terms

  • Cell Line
  • Hemadsorption*
  • Humans
  • Respiratory Tract Infections / virology*
  • Virus Cultivation / economics
  • Virus Cultivation / methods
  • Virus Diseases / diagnosis*
  • Viruses / isolation & purification*