Thrombus embolization into IVC filters during catheter-directed thrombolysis for proximal deep venous thrombosis

J Endovasc Ther. 2008 Oct;15(5):605-13. doi: 10.1583/08-2462.1.

Abstract

Purpose: To assess the frequency of embolization into retrievable inferior vena cava (IVC) filters during catheter-directed thrombolysis (CDT) and stent placement for acute iliocaval deep venous thrombosis (DVT).

Methods: Serial phlebograms from 40 patients (28 women; median age 32 years) consecutively treated with CDT for DVT during a 12-year period were retrospectively evaluated for visible emboli in the IVC filter. Clinical and procedural data extracted from a prospectively maintained database were evaluated to identify predictors for embolization into the filter.

Results: Visible emboli were found in 18 (45%) patients. Visible embolization to the IVC filter was less frequent in patients with a hypercoagulable disorder (n = 29, 31%) than in patients without a hypercoagulable disorder (n = 11, 69%; OR 0.1, 95% CI 0.02 to 0.56, p = 0.006). No patient developed clinical symptomatic pulmonary embolism or a complication related to the placement or retrieval of the IVC filter.

Conclusion: Thrombus embolization during CDT is a common phenomenon in patients with proximal DVT. Placement of a retrievable IVC filter during thrombolytic therapy can prevent silent and symptomatic pulmonary embolism.

MeSH terms

  • Adult
  • Catheterization*
  • Embolization, Therapeutic*
  • Female
  • Humans
  • Iliac Vein*
  • Male
  • Retrospective Studies
  • Stents*
  • Thrombolytic Therapy*
  • Vena Cava Filters*
  • Vena Cava, Inferior*
  • Venous Thrombosis / therapy*
  • Young Adult