Abstract

Aim: To assess the efficacy of the sirolimus-eluting stent when implanted in smaller caliber vessels using three-dimensional intravascular ultrasound (IVUS) analysis.

Methods: One hundred and twenty-three patients (69 sirolimus-coated Bx Velocity and 54 control) who underwent successful three-dimensional IVUS at follow up comprised this IVUS substudy from the SIRIUS (SIRolImUS-coated Bx Velocity stent in the treatment of patients with de novo coronary artery lesions) population. To evaluate the impact of vessel size, 2 groups were created using QCA reference vessel diameter (RVD; large vessel group: RVD>/=2.75 mm and small vessel group: RVD<2.75 mm).

Results: Sirolimus-eluting stents significantly reduced neointimal hyperplasia by the same relative magnitude within the stent in small vessels as well as in large vessels. Although sirolimus-eluting stents had favorable effects on lumen area at stent edges in larger vessels, the effect was less in smaller vessels, especially at the proximal edge. IVUS-detected adverse vessel response, such as late-acquired incomplete apposition, did not increase in smaller vessels even with relatively higher dose exposure.

Conclusion: Sirolimus-eluting stents showed inhibition of neointimal hyperplasia in small vessels compared to bare metal stents with no increase of vascular complications.

Publication types

  • Multicenter Study
  • Randomized Controlled Trial

MeSH terms

  • Angioplasty, Balloon, Coronary*
  • Coronary Artery Disease / diagnostic imaging*
  • Coronary Artery Disease / pathology
  • Coronary Artery Disease / therapy*
  • Coronary Restenosis / prevention & control
  • Drug-Eluting Stents*
  • Humans
  • Hyperplasia
  • Imaging, Three-Dimensional
  • Immunosuppressive Agents / administration & dosage
  • Sirolimus / administration & dosage*
  • Treatment Outcome
  • Tunica Intima / diagnostic imaging
  • Tunica Intima / pathology
  • Ultrasonography, Interventional

Substances

  • Immunosuppressive Agents
  • Sirolimus