Stent-graft deployment for aortic rupture after stenting for aortic recoarctation

Tex Heart Inst J. 2007;34(4):453-6.

Abstract

We present the case of a 62-year-old woman who presented with recoarctation and then experienced rupture of the aorta and severe clinical deterioration after a stent was deployed. She was treated immediately by intrastent deployment of a stent-graft, which resolved the extremely serious situation.

Keywords: Aortic coarctation/complications; aortic recoarctation/radiography/therapy/ultrasonography; aortic rupture/etiology/therapy; balloon dilatation/adverse effects; blood vessel prosthesis implantation; coronary angiography; stent-grafts; stents/adverse effects.

Publication types

  • Case Reports

MeSH terms

  • Anastomosis, Surgical
  • Aortic Coarctation / surgery*
  • Aortic Rupture / diagnosis
  • Aortic Rupture / etiology
  • Aortic Rupture / surgery*
  • Blood Vessel Prosthesis Implantation / instrumentation*
  • Cardiac Surgical Procedures / adverse effects*
  • Female
  • Humans
  • Magnetic Resonance Angiography
  • Middle Aged
  • Prosthesis Design
  • Recurrence
  • Reoperation
  • Stents*