Long-term retrospective study of the clinical performance of fiber posts

Am J Dent. 2007 Oct;20(5):287-91.

Abstract

Purpose: To retrospectively evaluate the long-term clinical performance of three types of fiber posts after a service period of 7-11 years.

Methods: 985 posts were included in the study: 615 Composiposts, 160 AEstethic Posts and 210 AEsthetic Plus Posts were placed into endodontically treated teeth. Four combinations of dentin adhesives/luting materials were used. Endodontic and prosthodontic results were recorded.

Results: A 7-11% failure rate was recorded for the three types of posts. A total of 79 failures were recorded: 39 due to endodontic reasons, one root fracture, one fiber post fracture, 17 crown dislodgements and 21 due to post debonding. The mechanical failures were always related to the lack of coronal tooth structure. The results indicated that fiber posts in combination with bonding/luting materials may be used routinely for restoring endodontically treated teeth. Mechanical failure of restored teeth with fiber posts can be related to the amount of residual coronal structure.

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Carbon / chemistry
  • Carbon Fiber
  • Composite Resins / chemistry*
  • Crowns
  • Dental Bonding
  • Dental Materials / chemistry*
  • Dental Prosthesis Design*
  • Dental Restoration Failure
  • Dentin-Bonding Agents / chemistry
  • Follow-Up Studies
  • Humans
  • Longitudinal Studies
  • Middle Aged
  • Periapical Diseases / etiology
  • Post and Core Technique / instrumentation*
  • Quartz / chemistry
  • Retrospective Studies
  • Root Canal Therapy
  • Stress, Mechanical
  • Tooth Fractures / etiology
  • Tooth Root / injuries
  • Tooth, Nonvital / therapy
  • Treatment Outcome

Substances

  • Carbon Fiber
  • Composite Resins
  • Dental Materials
  • Dentin-Bonding Agents
  • Quartz
  • Carbon