A method for the simultaneous determination of eight beta-lactam antibiotics (nafcillin, cloxacillin, oxacillin, dicloxacillin, ampicillin, amoxicillin, and penicillin G) in fortified milk samples of different origins has been proposed by using CZE with diode-array detection (CZE-DAD). Optimum separation was obtained on a 64.5 cm x 75 microm bubble cell capillary using 175 mM Tris buffer with 20% ethanol at pH 8.0. Methylparaben has been used as an internal standard (IS). Taking into account the lack of sensitivity of the UV-Vis detection, a solvent extraction/SPE method was applied for off-line preconcentration and sample cleanup, and also an on-line preconcentration methodology, such as large-volume sample stacking (LVSS) with polarity switching, was developed, providing LODs ranging from 2 to 10 microg/L. The method permits the quantification of these residues below the levels established in milk by the EU Regulation. Satisfactory recoveries ranging from 86 to 93% were also obtained in milk samples of different origins.