How many planes are required to get an accurate and timesaving measurement of left ventricular volume and function by real-time three-dimensional echocardiography in acute myocardial infarction?

Ultrasound Med Biol. 2007 Oct;33(10):1572-8. doi: 10.1016/j.ultrasmedbio.2007.04.013. Epub 2007 Jun 12.

Abstract

To derive the optimal cutting planes of real-time 3-D echocardiography (RT-3DE) for measuring left ventricular volume and ejection fraction (EF) in the presence of left ventricular regional wall motion abnormalities, 14 open-chest dogs were studied with RT-3DE full volume imaging and 2-D echocardiography (2DE) after left anterior descending coronary arteries were occluded for 90 min. Left ventricular end diastolic volume (EDV), end systolic volume (ESV), stroke volume (SV) and EF were measured off-line with 2DE and RT-3DE (2-, 4- and 8-plane) methods. The autopsy EDV was estimated by the volume of saline solution injected into the excised heart and served as the reference volume (RefV) for comparison with EDV measured by 2DE and RT-3DE. Agreement analysis was performed according to the method of Bland and Altman. There were excellent correlations between 2DE, RT-3DE (2-plane) and RT-3DE (4-plane) methods on one hand, and RT-3DE (8-plane) method on the other in the measurements of EDV, ESV and SV (r = 0.84-0.99). However, 2DE and RT-3DE (2-plane) measurements significantly underestimated RT-3DE (8-plane) (p < 0.01), whereas no significant differences between RT-3DE (4-plane) and RT-3DE (8-plane) were found in terms of EDV, ESV and SV measurements. The values of EF determined by 2DE, RT-3DE (2-plane) and RT-3DE (4-plane) methods correlated highly with that by RT-3DE (8-plane) (r = 0.82-0.98) and there was no significant difference between the two measurements. EDV values determined by 2DE, RT-3DE (2-plane), RT-3DE (4-plane) and RT-3DE (8-plane) correlated highly with RefV (r = 0.84, r = 0.92, r = 0.94 and r = 0.97, respectively) and there was no significant difference between RefV and EDV by RT-3DE (4-plane) and RT-3DE (8-plane). In contrast, EDV measured by 2DE and RT-3DE (2-plane) methods underestimated RefV significantly (p < 0.01). In conclusion, RT-3DE allows reliable and reproducible measurement of left ventricular volume and EF, even in the presence of left ventricular regional wall motion abnormalities. RT-3DE (4-plane) is the method of choice for an accurate and timesaving quantification of left ventricular volume and function.

Publication types

  • Comparative Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Animals
  • Dogs
  • Echocardiography
  • Echocardiography, Three-Dimensional / methods*
  • Female
  • Heart Ventricles / diagnostic imaging
  • Male
  • Models, Animal
  • Myocardial Infarction / diagnostic imaging*
  • Ventricular Dysfunction, Left / diagnostic imaging*