A high-performance liquid chromatographic method for determination of mitragynine in serum and its application to a pharmacokinetic study in rats

Biomed Chromatogr. 2007 Feb;21(2):176-83. doi: 10.1002/bmc.731.

Abstract

A simple HPLC technique for determining mitragynine levels in serum was developed. The separation system consisted of a C18 column heated to 35 degrees C, a methanol-water (80:20, v/v) mobile phase, a flow rate of 0.8 mL/min and detection in the ultraviolet at 225 nm. Mitragynine, with a retention time of 10.09 min, was well resolved from any interferences in human serum and the internal standard peak. The calibration curve was linear from 0.1 to 10 microg/mL (r = 0.9995). Extraction of mitragy-nine from alkalinized serum using diethyl ether gave a high recovery (>or=85%). The intra- and inter-day precisions of the method were 4.29-5.88%RSD and 7.06-8.45%RSD, respectively. The accuracy ranged from -9.54 to +0.67%DEV. The limit of detection was 0.03 microg/mL and the lower limit of quantification was 0.1 microg/mL. Mitragynine in the stock solution was stable during 30 days of storage at 4 degrees C. This method was successfully applied to determine the pharmacokinetic characteristics of mitragynine levels in the serum of rats after it was administered orally.

Publication types

  • Research Support, Non-U.S. Gov't
  • Validation Study

MeSH terms

  • Animals
  • Chromatography, High Pressure Liquid / methods*
  • Male
  • Mass Spectrometry / methods
  • Rats
  • Rats, Wistar
  • Secologanin Tryptamine Alkaloids / blood*
  • Secologanin Tryptamine Alkaloids / pharmacokinetics*

Substances

  • Secologanin Tryptamine Alkaloids
  • mitragynine