Minimization of diffusive attenuation in T2-weighted NMR images of porous solids using turboSPI

Solid State Nucl Magn Reson. 2006 Jun;29(4):267-71. doi: 10.1016/j.ssnmr.2005.09.002. Epub 2005 Oct 12.

Abstract

This communication presents the results of T2-weighted nuclear magnetic resonance imaging (MRI) of a water saturated porous volcanic rock using a fast single point imaging technique (turboSPI). Imaging porous materials with heterogeneously distributed mineral products, and air voids, using conventional imaging methods, which introduce T2-weighting by increasing the time between the excitation and refocusing pulses, often results in high diffusive signal losses and susceptibility distortion. T2-weighted images acquired of a water saturated porous rock using turboSPI with an effective echo time of 8.1 ms (actual inter-echo time of 0.9 ms) exhibit significantly decreased diffusive attenuation, compared to analogous images obtained with an inter-echo time of 8.1 ms.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Algorithms
  • Diffusion
  • Image Enhancement / methods*
  • Image Interpretation, Computer-Assisted / methods*
  • Magnetic Resonance Imaging / methods*
  • Magnetic Resonance Spectroscopy / methods*
  • Materials Testing / methods*
  • Porosity
  • Soil / analysis*
  • Water / analysis*

Substances

  • Soil
  • Water