Effectiveness and determinants of the long-term beta intracoronary brachytherapy results

Kardiol Pol. 2005 Jun;62(6):545-557; discussion 558.
[Article in English, Polish]

Abstract

Background: Effectiveness evaluation and search for the factors determining long-term results of beta intracoronary brachytherapy (ICBT) are of a special importance in an upcoming era of drug-eluting stents usage for a wide range of clinical indications: de novo and in-stent restenosis lesions.

Methods: One hundred forty eight consecutive patients (59.6+/-9.6 years, 72% men) treated with beta ICBT for in-stent restenosis (ISR) or de novo lesions were studied. There were 135 ISR in 121 patients and 31 de novo lesions in 27 patients. Follow-up coronary angiography was performed in all patients after a mean of 8.9+/-4.5 months. Detailed qualitative and quantitative angiographic analysis of pre-, peri- and postprocedural as well as follow-up angiograms was performed.

Results: Forty five percent of patients treated for de novo lesions were diabetic. Thirty five percent of all targets were located in vessels with a reference vessel diameter <2.5 mm. Furthermore, 77% of ISR lesions were in Class 1 according to the Mehran classification. The mean length of an irradiated segment was 37.6 mm. The overall recurrent restenosis rate was 28.3%. Multivariate analysis revealed that the reference vessel diameter and the presence of edge injury within the proximal 32P source dose-fall off were the only independent predictors of recurrent restenosis after ICBT (OR 0.46; 95%CI 0.24-0.89; p=0.021 and OR 2.55; 95%CI 1.23-5.25; p=0.011, respectively).

Conclusions: Recurrent restenosis after beta intracoronary brachytherapy treatment is negatively associated with the target vessel size. Presence of edge injury within the proximal 32P source dose-fall increases the frequency of recurrent renarrowing after ICBT. Our results indicate that target vessel size should be taken into account in optimising interventional strategy for ISR treatment: drug eluting stents versus intracoronary brachytherapy. Avoidance of edge injury within the proximal 32P source dose fall-off is strongly recommended while ICBT application.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Angioplasty, Balloon, Coronary*
  • Brachytherapy / methods*
  • Coronary Angiography
  • Coronary Restenosis / diagnostic imaging*
  • Coronary Stenosis / radiotherapy*
  • Female
  • Follow-Up Studies
  • Humans
  • Male
  • Middle Aged
  • Stents / adverse effects*
  • Time Factors
  • Treatment Outcome