Application of recently developed computer algorithm for automatic classification of unstructured radiology reports: validation study

Radiology. 2005 Feb;234(2):323-9. doi: 10.1148/radiol.2341040049. Epub 2004 Dec 10.

Abstract

Purpose: To validate the accuracy of Lexicon Mediated Entropy Reduction (LEXIMER), a new information theory-based computer algorithm developed by the authors for independent analysis and classification of unstructured radiology reports based on the presence of clinically important findings (F(T), where (T) represents "true") and recommendations for subsequent action (R(T)).

Materials and methods: The study was approved by the Human Research Committee of the institutional review board. Consecutive de-identified radiology reports (n = 1059) comprising results of barium studies (n = 99), computed tomography (n = 107), mammography (n = 90), magnetic resonance imaging (n = 108), nuclear medicine (n = 99), positron emission tomography (n = 106), radiography (n = 212), ultrasonography (n = 131), and vascular procedures (n = 107) were independently analyzed by two radiologists and then with LEXIMER to categorize the reports into F(T) and F(T)0 (containing or not containing clinically important findings) categories and R(T) and R(T)0 (containing or not containing recommendations for subsequent action) categories. Accuracy, sensitivity, specificity, and positive and negative predictive values of LEXIMER for placing reports into F(T) and F(T)0 and R(T) and R(T)0 categories were assessed by using appropriate statistical tests.

Results: There was strong interobserver concordance between the two radiologists for placing radiology reports into F(T) and R(T) categories (kappa = 0.9, P < .01). For the LEXIMER program, accuracy, sensitivity, specificity, and positive and negative predictive values, respectively, were 97.5% (95% confidence interval [CI]: 96.6%, 98.5%), 98.9% (95% CI: 97.9%, 99.6%), 94.9% (95% CI: 93.1%, 96.0%), 97.5% (95% CI: 96.6%, 98.0%), and 97.7% (95% CI: 95.8%, 98.8%) for placing radiology reports into F(T) and F(T)0 categories and 99.6% (95% CI: 99.2%, 99.9%), 98.2% (95% CI: 95.0%, 99.6%), 99.9% (95% CI: 99.4%, 99.99%), 99.4% (95% CI: 96.3%, 99.9%), and 99.7% (95% CI: 98.9%, 99.9%) for placing reports into R(T) and R(T)0 categories.

Conclusion: LEXIMER is an accurate automated engine for evaluating the percentage positivity of clinically important findings and rates of recommendation for subsequent action in unstructured radiology reports.

Publication types

  • Evaluation Study

MeSH terms

  • Algorithms*
  • Decision Making, Computer-Assisted*
  • False Negative Reactions
  • False Positive Reactions
  • Humans
  • Magnetic Resonance Imaging
  • Mammography
  • Observer Variation
  • Radiology Information Systems*
  • Radionuclide Imaging
  • Sensitivity and Specificity
  • Tomography, Emission-Computed, Single-Photon
  • Tomography, X-Ray Computed
  • Ultrasonography