[Diode laser cyclophotocoagulation--effect on intraocular pressure in comparison with cyclodiathermy under the scleral flap]

Klin Oczna. 2004;106(1-2 Suppl):196-8.
[Article in Polish]

Abstract

The aim of this study was to retrospectively analyze intraocular pressure and state of the eyeball in patients treated with diode laser, and to compare the outcomes with a group of patients after cyclodiahtermy under the scleral flap. We analyzed: visual acuity, IOP, percentage of lowering the IOP from the beginning, subjective patients' feelings of pain and complications.

Conclusions: TSCPC is safe for patients and may be repeated, if needed. Laser cyclodestruction gives new possibilities in noninvasive IOP lowering with less complications than cyclodiahtermy, without changes in patient's visual functions.

Publication types

  • Comparative Study
  • English Abstract

MeSH terms

  • Aged
  • Electrocoagulation / methods*
  • Female
  • Glaucoma / physiopathology
  • Glaucoma / surgery*
  • Humans
  • Intraocular Pressure*
  • Laser Coagulation / methods*
  • Male
  • Retrospective Studies
  • Sclera / surgery*
  • Treatment Outcome