A prospective, randomized evaluation of the effects of epidural needle rotation on the distribution of epidural block

Anesth Analg. 2004 May;98(5):1473-8, table of contents. doi: 10.1213/01.ane.0000111113.45743.b8.

Abstract

We evaluated the effects of turning the tip of the Tuohy needle 45 degrees toward the operative side before threading the epidural catheter (45 degrees -rotation group, n = 24) as compared to a conventional insertion technique with the tip of the Tuohy needle oriented at 90 degrees cephalad (control group, n = 24) on the distribution of 10 mL of 0.75% ropivacaine with 10 microg sufentanil in 48 patients undergoing total hip replacement. The catheter was introduced 3 to 4 cm beyond the tip of the Tuohy needle. A blinded observer recorded sensory and motor blocks on both sides, quality of analgesia, and volumes of local anesthetic used during the first 48 h of patient-controlled epidural analgesia. Readiness to surgery required 21 +/- 6 min in the control group and 17 +/- 7 min in the 45 degree-rotation group (P > 0.50). The maximum sensory level reached on the operative side was T10 (T10-7) in the control group and T9 (T10-6) in the 45 degree-rotation group (P > 0.50); whereas the maximum sensory level reached on the nonoperative side was T10 (T12-9) in the control group and L3 (L5-T12) in the 45 degree-rotation group (P = 0.0005). Complete motor blockade of the operative limb was achieved earlier in the 45 degree-rotation than in the control group, and motor block of the nonoperative side was more intense in patients in the control group. Two-segment regression of sensory level on the surgical side was similar in the two groups, but occurred earlier on the nonoperative side in the 45 degree-rotation group (94 +/- 70 min) than in the control group (178 +/- 40 min) (P = 0.0005). Postoperative analgesia was similar in the 2 groups, but the 45 degree-rotation group consumed less local anesthetic (242 +/- 35 mL) than the control group (297 +/- 60 mL) (P = 0.0005). We conclude that the rotation of the Tuohy introducer needle 45 degrees toward the operative side before threading the epidural catheter provides a preferential distribution of sensory and motor block toward the operative side, reducing the volume of local anesthetic solution required to maintain postoperative analgesia.

Implications: Turning the Tuohy introducer needle 45 degrees toward the operative side before threading the epidural catheter is a simple maneuver that produces a preferential distribution of epidural anesthesia and analgesia toward the operative side, minimizing the volume of local anesthetic required to provide adequate pain relief after total hip arthroplasty.

Publication types

  • Clinical Trial
  • Randomized Controlled Trial

MeSH terms

  • Aged
  • Analgesia, Epidural / adverse effects
  • Analgesia, Epidural / instrumentation
  • Analgesia, Epidural / methods*
  • Analgesia, Patient-Controlled
  • Arthroplasty, Replacement, Hip
  • Blood Pressure / drug effects
  • Blood Pressure / physiology
  • Double-Blind Method
  • Female
  • Humans
  • Male
  • Middle Aged
  • Monitoring, Intraoperative
  • Needles*
  • Nerve Block
  • Orthopedic Procedures
  • Pain / prevention & control
  • Pain, Postoperative / drug therapy
  • Pain, Postoperative / epidemiology
  • Pilot Projects
  • Prospective Studies
  • Sensation / drug effects