[Determination of finasteride in human plasma by HPLC-MS]

Yao Xue Xue Bao. 2003 Jun;38(6):455-7.
[Article in Chinese]

Abstract

Aim: To develop an HPLC-MS assay for determination of finasteride in human plasma and to investigate the bioequivalence in healthy volunteers.

Methods: After alkalization with sodium hydroxide, plasma was extracted with ethyl acetate and separated using a C18 column with a mobile phase of methanol-water (85:15). LC-ESI-MS was performed in the selected ion monitoring (SIM) mode using target ions at m/z 395 for finasteride and m/z 407 for the IS. The fragmentor voltage was 120 V. A randomized crossover design was performed in 20 healthy volunteers. In the two study periods, a single 10 mg dose of each tablet was administered to each volunteer.

Results: Calibration curves were linear over the range 1-200 micrograms.L-1 (r = 0.9986). The limit of determination for finasteride in plasma was 0.05 microgram.L-1. The recovery of finasteride from plasma was in the range of 85.9%-98.7%. The results of variance analysis and two one-side t-test showed that there was no significant difference between the two formulations in the AUC and Cmax.

Conclusion: The assay was proved to be sensitive, accurate and convenient. The two formulations were bioequivalent.

Publication types

  • Clinical Trial
  • English Abstract
  • Randomized Controlled Trial

MeSH terms

  • Adult
  • Area Under Curve
  • Chromatography, High Pressure Liquid
  • Cross-Over Studies
  • Enzyme Inhibitors / blood*
  • Enzyme Inhibitors / pharmacokinetics
  • Finasteride / blood*
  • Finasteride / pharmacokinetics
  • Gas Chromatography-Mass Spectrometry
  • Humans
  • Male
  • Random Allocation
  • Spectrometry, Mass, Electrospray Ionization
  • Therapeutic Equivalency

Substances

  • Enzyme Inhibitors
  • Finasteride