Urinary cannabinoid detection times after controlled oral administration of delta9-tetrahydrocannabinol to humans

Clin Chem. 2003 Jul;49(7):1114-24. doi: 10.1373/49.7.1114.

Abstract

Background: Urinary cannabinoid excretion and immunoassay performance were evaluated by semiquantitative immunoassay and gas chromatography-mass spectrometry (GC/MS) analysis of metabolite concentrations in 4381 urine specimens collected before, during, and after controlled oral administration of tetrahydrocannabinol (THC).

Methods: Seven individuals received 0, 0.39, 0.47, 7.5, and 14.8 mg THC/day in this double-blind, placebo-controlled, randomized, clinical study conducted on a closed research ward. THC doses (hemp oils with various THC concentrations and the therapeutic drug Marinol) were administered three times daily for 5 days. All urine voids were collected over the 10-week study and later tested by Emit II, DRI, and CEDIA immunoassays and by GC/MS. Detection rates, detection times, and sensitivities, specificities, and efficiencies of the immunoassays were determined.

Results: At the federally mandated immunoassay cutoff (50 microg/L), mean detection rates were <0.2% during ingestion of the two low doses typical of current hemp oil THC concentrations. The two high doses produced mean detection rates of 23-46% with intermittent positive tests up to 118 h. Maximum metabolite concentrations were 5.4-38.2 microg/L for the low doses and 19.0-436 micro g/L for the high doses. Emit II, DRI, and CEDIA immunoassays had similar performance efficiencies of 92.8%, 95.2%, and 93.9%, respectively, but differed in sensitivity and specificity.

Conclusions: The use of cannabinoid-containing foodstuffs and cannabinoid-based therapeutics, and continued abuse of oral cannabis require scientific data for accurate interpretation of cannabinoid tests and for making reliable administrative drug-testing policy. At the federally mandated cannabinoid cutoffs, it is possible but unlikely for a urine specimen to test positive after ingestion of manufacturer-recommended doses of low-THC hemp oils. Urine tests have a high likelihood of being positive after Marinol therapy. The Emit II and DRI assays had adequate sensitivity and specificity, but the CEDIA assay failed to detect many true-positive specimens.

Publication types

  • Clinical Trial
  • Comparative Study
  • Randomized Controlled Trial
  • Research Support, U.S. Gov't, Non-P.H.S.
  • Research Support, U.S. Gov't, P.H.S.

MeSH terms

  • Administration, Oral
  • Adult
  • Cannabis*
  • Double-Blind Method
  • Dronabinol / administration & dosage
  • Dronabinol / urine*
  • Female
  • Gas Chromatography-Mass Spectrometry
  • Humans
  • Immunoassay
  • Male
  • Plant Oils / administration & dosage
  • Plant Oils / metabolism*
  • Reference Values
  • Sensitivity and Specificity
  • Substance Abuse Detection / methods*
  • Time Factors

Substances

  • Plant Oils
  • Dronabinol