[Qualitative and quantitative methods of chlorogenic acid in commercial Herba Artemisiae Scopariae]

Zhongguo Zhong Yao Za Zhi. 2002 Apr;27(4):267-9.
[Article in Chinese]

Abstract

Objective: To develop the identification and assay for chlorogenic acid in commercial Herba Artemisiae Scopariae.

Method: TLC method was used for identification with silica gel G plate and butyl acetate-formic acid-water (7:2.5:2.5) upper layer as a developing solvent. Chlorogenic acid in 85% methanolic extract was separated on the ODS column with methonal-3% acetic acid solution (15:85) as mobile phase. The detection wavelength was 327 nm.

Result: The qualitative method is repeatable. Chlorogenic acid in extracts is well separated, relationship of injection amount and peak area is linear (r = 0.9998) within the range of 0.075-0.6 microgram. The average recovery is 100.9% and repeatability is 1.4%. Ten samples purchased from different areas in the country were identified and quantified with the methods.

Conclusion: The methods and data could be used for quality control.

Publication types

  • English Abstract
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Artemisia / chemistry*
  • Chlorogenic Acid / analysis*
  • Plants, Medicinal / chemistry*
  • Quality Control

Substances

  • Chlorogenic Acid