Resin adhesion to carious dentin

Am J Dent. 2003 Feb;16(1):47-52.

Abstract

Purpose: To investigate the microtensile bond strength (microTBS) of a self-etching priming adhesive system to normal, caries-affected and caries-infected dentin, and to observe the ultrastructure of the resin-dentin interface by transmission electron microscopy (TEM).

Materials and methods: Twelve extracted human molar teeth with deep occlusal caries were stained with caries detector solution and ground flat occlusally. The red-stained soft dentin was classified as caries-infected. The surrounding discolored dentin was classified as caries-affected dentin. The surrounding normal dentin served as a control. The entire flat surface was bonded with Clearfil Liner Bond 2V (CV) and covered with resin composite to form a composite crown 5 mm high. One day later the specimens were serially sectioned vertically into multiple slabs 0.8 mm thick. Under microscopic observation, the specimens were divided into normal or caries-infected or caries-affected dentin. These regions were isolated by cutting away the remaining dentin to form hour-glass shapes with the smallest surface area at the test site. After measuring the areas, the specimens were fixed to a microtensile tester and pulled under tension to failure. Additional slabs that were not used for bond strength tests were processed for TEM. Bond strength data were analyzed by Kruskal-Wallis one-way ANOVA and Student-Newman-Keuls multiple comparisons.

Results: The microTBS of CV to normal, caries-affected and caries-infected dentin were 45 +/- 10 MPa, 30 +/- 10 MPa, 10 +/- 5 MPa, respectively. TEM images showed that CV formed thin hybrid layers that were less than 1 microm thick in normal dentin, but that were between 6-8 microm thick in caries-affected dentin. Bacteria were only sparsely observed in the dentin tubules of bonded caries-affected dentin. However, in caries-infected dentin, an unusual interface was seen in which carious bacteria within disorganized non-banded collagen fibrils could be seen embedded by the adhesive. The hybrid layer in caries-infected dentin was found to be 30-60 microm thick.

Publication types

  • Comparative Study
  • Research Support, U.S. Gov't, P.H.S.

MeSH terms

  • Acid Etching, Dental / methods
  • Dental Bonding*
  • Dental Caries / pathology
  • Dental Caries / prevention & control*
  • Dental Cavity Preparation / methods*
  • Dental Marginal Adaptation*
  • Dental Stress Analysis
  • Dentin / pathology
  • Dentin / ultrastructure
  • Dentin-Bonding Agents / therapeutic use*
  • Humans
  • In Vitro Techniques
  • Methacrylates / therapeutic use*
  • Microscopy, Electron

Substances

  • Clearfil Liner Bond 2
  • Dentin-Bonding Agents
  • Methacrylates