Obtaining rigidity in total phalloplasty: experience with 35 patients

J Urol. 2003 Jan;169(1):221-3. doi: 10.1016/S0022-5347(05)64072-4.

Abstract

Purpose: The combination of a neourethra and erection prosthesis in a single neophallus in the female-to-male transsexual remains a challenge. The outcome reported in the literature is disappointing. We report our experience with 35 patients.

Materials and methods: Between August 1996 and December 2001, 35 patients underwent implantation surgery. A 1-piece hydraulic Dynaflex prosthesis (American Medical Systems, Minnetonka, Minnesota) was used in 10 patients, while a 3-piece hydraulic CXM and CX (American Medical Systems) prosthesis was placed in 9 and 16, respectively. The 1-piece model was withdrawn from the market in 1997. Thereafter a 3-piece prosthesis was implanted.

Results: Of 10 patients in the 1-piece group prosthesis implantation was uneventful in 8. In 2 patients with technical failure the prosthesis was replaced, including 1 in whom the new prosthesis was removed due to infection and successfully replaced by a 3-piece prosthesis. To date at a mean followup of 3.5 years 9 patients have a 1-piece hydraulic prosthesis in place. In the 3-piece prosthesis group of 25 patients implantation was uneventful in 20. In 1 patient infection and partial necrosis of the neophallus developed, 2 had infection, in 1 a cylinder perforated the tip of the phallus and in 1 technical failure occurred. Of the latter 4 patients the prosthesis was replaced successfully in 2 patients, while the other 2 are on the waiting list. The patient with partial necrosis of the phallus is no longer a candidate for an erection prosthesis. To date at a mean followup of 1.8 years 23 patients have a 3-piece hydraulic prosthesis in place. A single patient in the 1-piece group has a 3-piece CX prosthesis.

Conclusions: Good results were observed after implantation of the Dynaflex prosthesis in patients who underwent total phalloplasty. This model is no longer available today. For the more complex 3-piece CX and CXM prostheses implantation results are comparable to those of the 1-piece model.

MeSH terms

  • Device Removal
  • Female
  • Follow-Up Studies
  • Humans
  • Male
  • Penile Erection
  • Penile Implantation* / adverse effects
  • Penis / surgery*
  • Transsexualism / surgery*