Effects of a new modified, balanced hydroxyethyl starch preparation (Hextend) on measures of coagulation

Br J Anaesth. 2002 Nov;89(5):722-8. doi: 10.1093/bja/aef242.

Abstract

Background: Hydroxyethyl starch (HES) may affect blood coagulation. We studied the effects of a modified, balanced, high-molecular weight [mean molecular weight (MW) 550 kDa], high-substituted [degree of substitution (DS) 0.7] HES preparation (Hextend) on coagulation in patients undergoing major abdominal surgery.

Methods: Patients were allocated randomly to receive Hextend) (n=21), lactated Ringer's solution (RL, n=21) or 6% HES with a low MW (130 kDa) and a low DS (0.4) (n=21). The infusion was started after induction of anaesthesia and continued until the second postoperative day to maintain central venous pressure between 8 and 12 mm Hg. Activated thrombelastography (TEG) was used to assess coagulation. Different activators were used (extrinsic and intrinsic activation of TEG) and aprotinin was added to assess hyperfibrinolytic activity (ApTEG). We measured onset of coagulation [coagulation time (CT=reaction time, r)], the kinetics of clot formation [clot formation time (CFT=coagulation time, k)] and maximum clot firmness (MCF=maximal amplitude, MA). Measurements were performed after induction of anaesthesia, at the end of surgery, 5 h after surgery and on the mornings of the first and second days after surgery.

Results: Significantly more HES 130/0.4 [2590 (SD 260) ml] than Hextend) [1970 (310) ml] was given. Blood loss was greatest in the Hextend) group and did not differ between RL- and HES 130/0.4-treated patients. Baseline TEG data were similar and within the normal range. CT and CFT were greater in the Hextend) group immediately after surgery, 5 h after surgery and on the first day than in the two other groups. ApTEG MCF also changed significantly in the Hextend) patients, indicating more pronounced fibrinolysis. Volume replacement using RL caused moderate hypercoagulability, shown by a decrease in CT.

Conclusion: A modified, balanced high-molecular weight HES with a high degree of substitution (Hextend) adversely affected measures of coagulation in patients undergoing major abdominal surgery, whereas a preparation with a low MW and low DS affected these measures of haemostasis less. Large amounts of RL decreased the coagulation time.

Publication types

  • Clinical Trial
  • Randomized Controlled Trial
  • Retracted Publication

MeSH terms

  • Abdominal Neoplasms / blood
  • Abdominal Neoplasms / surgery*
  • Aged
  • Anesthesia, Epidural
  • Blood Coagulation / drug effects*
  • Blood Pressure / drug effects
  • Female
  • Heart Rate / drug effects
  • Humans
  • Hydroxyethyl Starch Derivatives / pharmacology*
  • Isotonic Solutions / pharmacology
  • Male
  • Middle Aged
  • Plasma Substitutes / pharmacology*
  • Ringer's Lactate
  • Thrombelastography
  • Whole Blood Coagulation Time

Substances

  • Hydroxyethyl Starch Derivatives
  • Isotonic Solutions
  • Plasma Substitutes
  • Ringer's Lactate