PCDD and PCDF exposures in workers and controls living near an industrial waste incinerator

Chemosphere. 2001 May-Jun;43(4-7):985-7. doi: 10.1016/s0045-6535(00)00459-8.

Abstract

This study measured the levels of 17 congeners of PCDDs/PCDFs in serum to compare the levels between potentially exposed workers at an industrial waste incinerator and any residents with no known exposures. The 1,2,3,6,7,8- and 1,2,3,7,8,9-HxCDD were detected in serum of workers but in controls. Likewise, 1,2,3,7,8-PeCDF, 1,2,3,6,7,8- and 1,2,3,7,8,9-HxCDF were detected only in serum of workers. The international toxic equivalent (TEQ) levels of PCDDs/PCDFs in sera of workers are much higher than in controls. Among PCDDs, the proportion of total concentration and TEQ level is dominated predominantly by 1,2,3,6,7,8- and 1,2,3,7,8,9-HxCDD. We need extensive studies to estimate human exposure and are continuing this investigation.

MeSH terms

  • Adult
  • Benzofurans / blood*
  • Dibenzofurans, Polychlorinated
  • Environmental Exposure*
  • Female
  • Humans
  • Incineration
  • Industry
  • Male
  • Middle Aged
  • Occupational Exposure*
  • Polychlorinated Dibenzodioxins / analogs & derivatives
  • Polychlorinated Dibenzodioxins / blood*
  • Reference Values
  • Refuse Disposal*
  • Soil Pollutants / blood*

Substances

  • Benzofurans
  • Dibenzofurans, Polychlorinated
  • Polychlorinated Dibenzodioxins
  • Soil Pollutants