Bone marrow uptake of 99mTc-MIBI in patients with multiple myeloma

Eur J Nucl Med. 2001 Feb;28(2):214-20. doi: 10.1007/s002590000434.

Abstract

In a previous study, we showed the ability of technetium-99m methoxyisobutylisonitrile (99mTc-MIBI) scan to identify active disease in patients with multiple myeloma (Eur J Nucl Med 1998; 25: 714-720). In particular, a semiquantitative score of the extension and intensity of bone marrow uptake was derived and correlated with both the clinical status of the disease and plasma cell bone marrow infiltration. In order to estimate quantitatively 99mTc-MIBI bone marrow uptake and to verify the intracellular localization of the tracer, bone marrow samples obtained from 24 multiple myeloma patients, three patients with monoclonal gammopathy of undetermined significance (MGUS) and two healthy donors were studied for in vitro uptake. After centrifugation over Ficoll-Hypaque gradient, cell suspensions were incubated with 99mTc-MIBI and the uptake was expressed as the percentage of radioactivity specifically retained within the cells. The cellular localization of the tracer was assessed by micro-autoradiography. Twenty-two out of 27 patients underwent 99mTc-MIBI scan within a week of bone marrow sampling. Whole-body images were obtained 10 min after intravenous injection of 555 MBq of the tracer; the extension and intensity of 99mTc-MIBI uptake were graded using the semiquantitative score. A statistically significant correlation was found between in vitro uptake of 99mTc-MIBI and both plasma cell infiltration (Pearson's coefficient of correlation r=0.69, P<0.0001) and in vivo score (Spearman rank correlation coefficient r=0.60, P<0.01). No specific tracer uptake was found in bone marrow samples obtained from the two healthy donors. Micro-autoradiography showed localization of 99mTc-MIBI inside the plasma cells infiltrating the bone marrow. Therefore, our findings show that the degree of tracer uptake both in vitro and in vivo is related to the percentage of infiltrating plasma cells which accumulate the tracer in their inner compartments.

Publication types

  • Clinical Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Autoradiography
  • Bone Marrow / diagnostic imaging*
  • Bone Marrow / metabolism*
  • Bone Marrow Cells / diagnostic imaging
  • Bone Marrow Cells / metabolism
  • Female
  • Humans
  • Male
  • Middle Aged
  • Multiple Myeloma / diagnostic imaging*
  • Multiple Myeloma / metabolism*
  • Plasma Cells / diagnostic imaging
  • Plasma Cells / metabolism
  • Radionuclide Imaging
  • Radiopharmaceuticals / pharmacokinetics*
  • Technetium Tc 99m Sestamibi / pharmacokinetics*
  • Whole-Body Counting

Substances

  • Radiopharmaceuticals
  • Technetium Tc 99m Sestamibi