Serial volumetric intravascular ultrasound analysis of the efficacy of beta irradiation in preventing recurrent in-stent restenosis

Am J Cardiol. 2000 Mar 1;85(5):651-3, A10. doi: 10.1016/s0002-9149(99)00827-9.

Abstract

We compared postintervention and follow-up intravascular ultrasound findings of 25 patients from the beta-Washington Radiation for InStent restenosis Trial (in which all patients received radiation) and 75 patients from the Washington Radiation for InStent restenosis Trial (in which patients were randomized to gamma irradiation). The decrease in lumen volume was similar for beta versus gamma and less in both gamma versus placebo and beta versus placebo; the increase in intimal hyperplasia volume was similar for beta versus gamma and greater in both beta versus placebo and gamma versus placebo.

Publication types

  • Clinical Trial
  • Comparative Study
  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Beta Particles / therapeutic use*
  • Brachytherapy*
  • Coronary Disease / diagnostic imaging*
  • Coronary Disease / prevention & control
  • Coronary Disease / radiotherapy*
  • Follow-Up Studies
  • Humans
  • Iridium Radioisotopes / therapeutic use
  • Recurrence
  • Stents*
  • Time Factors
  • Ultrasonography, Interventional*
  • Yttrium Radioisotopes / therapeutic use

Substances

  • Iridium Radioisotopes
  • Yttrium Radioisotopes