Ultrasound for diagnosis of scaphoid fractures

J Hand Surg Br. 2000 Aug;25(4):369-71. doi: 10.1054/jhsb.2000.0432.

Abstract

We investigated the diagnostic value of two different ultrasound scanning methods for the early diagnosis of acute scaphoid fractures. Fifty-seven patients with ten scaphoid fractures were assessed within a week of injury. The accuracy of the ultrasound assessment was 84% and its specificity was 91%. However, its sensitivity was only 50%. We conclude that ultrasound examination is unreliable for the diagnosis of acute scaphoid fractures.

MeSH terms

  • Adult
  • Female
  • Fractures, Bone / diagnostic imaging*
  • Humans
  • Male
  • Predictive Value of Tests
  • Scaphoid Bone / diagnostic imaging
  • Scaphoid Bone / injuries*
  • Sensitivity and Specificity
  • Time Factors
  • Ultrasonography, Doppler