Low-dose (1 microgram) adrenocorticotrophin (ACTH) stimulation as a screening test for impaired hypothalamo-pituitary-adrenal axis function: sensitivity, specificity and accuracy in comparison with the high-dose (250 microgram) test

Clin Endocrinol (Oxf). 2000 May;52(5):633-40. doi: 10.1046/j.1365-2265.2000.00984.x.

Abstract

Objective: We have shown previously that in contrast to the standard high-dose 250-microgram ACTH test, a low-dose 1-microgram ACTH stimulation test correctly identified all patients with pituitary disease who had impaired hypothalamo-pituitary-adrenal (HPA) function. In this study we further compared the performances of these two tests as screening procedures for possible HPA impairment.

Design: A comparison of the 1-microgram and the 250-microgram ACTH stimulation tests in healthy controls and in patients with pituitary disease whose HPA axis status was characterized formally by a gold standard test.

Subjects: A total of 89 subjects were investigated: 27 healthy normal controls, 43 patients with pituitary disease and normal HPA function, and 19 patients with various pituitary diseases and impaired HPA function.

Measures: All 89 subjects underwent stimulation with 1 microgram ACTH; 80 also underwent the high-dose 250-microgram ACTH test. A receiver operating characteristic analysis (ROC) was performed to compare the tests.

Results: Using a stimulated cortisol > 500 nmol/l as the criterion for a normal response, the 1-microgram ACTH stimulation identified 18 of the 19 subjects with impaired HPA function (94.7% sensitivity with a likelihood ratio of 0.0588 for a negative test). In contrast, 15/16 passed the high-dose test (a 6.2% sensitivity with a likelihood ratio of 0.875 for a negative test). All normal controls, and 36/43 patients with preserved HPA function, passed the 1-microgram ACTH test (90% specificity). This degree of accuracy was unrivalled by the high dose test at all the cut-off levels considered.

Conclusions: More sensitive and accurate, the low-dose 1-microgram ACTH test is as simple and safe as the standard 250-microgram test. We suggest it should replace it in screening for adrenal insufficiency.

Publication types

  • Comparative Study

MeSH terms

  • Adrenal Insufficiency / diagnosis*
  • Adrenocorticotropic Hormone / administration & dosage*
  • Adult
  • Case-Control Studies
  • Drug Administration Schedule
  • Female
  • Humans
  • Hydrocortisone / blood*
  • Hypothalamo-Hypophyseal System / physiopathology*
  • Male
  • Middle Aged
  • Pituitary Diseases / diagnosis
  • Pituitary Function Tests
  • Pituitary-Adrenal System / physiopathology*
  • Predictive Value of Tests
  • ROC Curve
  • Sensitivity and Specificity
  • Stimulation, Chemical

Substances

  • Adrenocorticotropic Hormone
  • Hydrocortisone