Gap-junctional coupling measured by flow cytometry

Exp Cell Res. 2000 Feb 25;255(1):40-6. doi: 10.1006/excr.1999.4760.

Abstract

A method is described which reliably quantifies the degree of intercellular communication via gap junctions by combining a dye-loading technique with fluorescence-activated flow cytometry. Our experiments expand former measurements of other groups by analyzing the time- and density-dependent onset of coupling with a fixed ratio of donor to recipient cells. The high sensitivity of this technique provides a better resolution than the microelectrode technique and allows the detection of small changes in gap-junctional coupling by examining a large number of cells in a single experiment. Suspended cells were loaded with the membrane-permeable dye calcein AM, which is intracellularly hydrolyzed by nonspecific esterases, and the resulting polyanionic calcein is thus trapped inside these donor cells. Gap junctions, however, are permeable for this fluorescent dye, as can be observed when suspended donor cells are added to recipient cells (i.e., monolayer cultures) in which case cell-cell contact is established within less than 60 min. In addition, one of these two cell populations can also be stained with a membrane-resident dye (e.g., DiI), which facilitates the identification of different cell populations (donors, recipients, and noncoupled cells) not only by epifluorescence microscopy but also by flow cytometry. Our analyses reveal that junctional coupling depends not only on the connexin type (homo- or heterotypic junction) but also on the origin (species) of the contacting cells (homo- or heterospecific contact). We confirm earlier reports in which homotypic-homospecific coupling was demonstrated with different techniques in connexin-transfected HeLa and RIN cells as well as in BICR/M1R(k) and 3T3/SV40 cells. In contrast to other publications, we show that a significant heterotypic-homospecific coupling between Cx40- and Cx43-HeLa transfectants can be resolved, whereas no coupling was detected for heterotypic-heterospecific contacts between Cx40-HeLa transfectants and the Cx43-expressing cell lines BICR/M1R(k), 3T3/SV40, and RIN.

MeSH terms

  • 3T3 Cells
  • Animals
  • Cell Communication / physiology
  • Cell Count
  • Flow Cytometry / methods*
  • Fluoresceins / metabolism
  • Fluorescent Dyes / metabolism
  • Gap Junctions / physiology*
  • HeLa Cells
  • Humans
  • Mice
  • Rats
  • Tumor Cells, Cultured

Substances

  • Fluoresceins
  • Fluorescent Dyes
  • calcein AM